Myron L Instruments

Analog Handheld

Myron L Instruments

Readings You Can Count On

No water supply is completely pure. Every industrial, commercial, or natural source contains dissolved solids or salts. These impurities contribute to scale, corrosion, poor taste, and environmental pollution that endanger animal and plant life.

Myron L Company has two proven ways to measure such impurities. Our DS Meters™ provide fast, accurate, on-the-spot measurements of total dissolved solids (TDS) or conductivity. pDS Meters™ test conductivity or TDS, plus pH. Readings from their highly stable circuitry help assure product quality, prevent equipment damage and verify in-line instrumentation in a wide range of applications, some of which are listed above.

Unique Field-Tested Design

Our unique, durable, field-tested design has evolved over more than 40 years, making Myron L instruments among the most reliable and popular of their kind in the world. They're lightweight and compact, yet Myron L's DS and pDS Meters are also tough, with rugged, taut-band meter movements. Put our meters to the test. Even after years of rough field service, they'll surpass your expectations of accuracy, reliability and simplicity.

Accurate readings in three easy steps

Rinse and fill cell cup

Select Cond/TDS range

Push button to indicate reading


Select From Our Complete Line of DS/pDS Meters


DS CONDUCTIVITY / TDS METERS

Part Number

Description

512M2

DS Conductivity Meter: 0-50 µM/µS

512M3

DS Conductivity Meter: 0-500 µM/µS

512M4

DS Conductivity Meter : 0-2500 µM/µS

512M5

DS Conductivity Meter: 0-5000 µM/µS

512M10

DS Conductivity Meter: 0-10,000 µM/µS

512T2

DS TDS Meter: 0-50 ppm

512T3

DS TDS Meter: 0-500 ppm

512T4

DS TDS Meter: 0-2500 ppm

512T4H

HYDROPONICS™ DS TDS Meter: 0-2500 ppm

512T5

DS TDS Meter: 0-5000 ppm

512T5D

POOLMETER™ DS TDS Meter:

0-5000 ppm/442, 0-5000 ppm/NaCl

512T10

DS TDS Meter: 0-10,000 ppm

532M1

DS Conductivity Meter: 0-50, 500, 5000 µM/µS

532T1

DS TDS Meter: 0-50, 500, 5000 ppm

532T2

DS TDS Meter: 0-25, 250, 2500 ppm

AG-5

AGRI-METER™ DS Conductivity Meter: 0-5 millimhos

D-1

DIALYSATE METER™ DS Conductivity Meter:

11-15 millimhos

D-2

DIALYSATE METER™ DS Conductivity Meter:

0-10 & 0-20 millimhos

EP-10

DS Conductivity Meter: 0-10, 100, 1000, 10,000 µM/µS

EP

DS Conductivity/Resistivity Meter: 0-0.5, 5, 50, 500, 5000 µM/µS; 2-30 MΩ

RO-1

RO METER™ DS TDS Meter: 0-1250 ppm (with color band)

RO-1NC

RO METER™ DS TDS Meter: 0-1250 ppm (no color band)

pDS pH/CONDUCTIVITY / TDS METERS

Part Number

Description

AG6/PH

AGRI-METER™ pDS pH/Conductivity Meter:

0-5 millimhos; 2-12 pH

EP11/PH

pDS pH/Conductivity Meter: 0-10, 100, 1000,

10,000 µM/µS; 2-12 pH

M6/PH

pDS pH/Conductivity Meter: 0-5000 µM/µS; 2-12 pH

T2/PH

pDS pH/TDS Meter:

0-50, 500, 5000 ppm; 2-12 pH

T6/PH

pDS pH/TDS Meter: 0-5000 ppm; 2-12 pH

T6/PHH

HYDROPONICS™ pDS pH/TDS Meter:

0-5000 ppm; 2-12 pH


Accessories we recommend

Standard Solutions: NIST Standard Solutions & pH Buffers All Myron L instruments are factory calibrated with Standard Solutions of known conductivity/TDS value and (when appropriate) with pH buffer values 4, 7 and 10. These solutions and buffers are traceable to the U.S. Government's National Institute of Standards and Technology. Periodic recalibration with the appropriate Standard Solutions and pH Buffers will help maintain the accuracy of your instrument. See the table above for recommendations. Note: pH 7 Buffer is especially important and should be used every 1- 2 weeks.

Range Extender: Increases the conductivity/TDS range by a factor of 10 when inserted into the sample filled cell cup. Not available for model 512T10. Model: RE-10

Porta-Kit (pDS only): Hard foam-lined case with 2 oz. bottles of pH Buffers 4, 7 and 10 and conductivity Standard Solution. Model: PK3 for models M6/PH, T2/PH & T6/PH; Model: PK7 for EP11/PH.

Replacement pH Sensor: Replacement pH Sensor is a unique non-refillable KCl gel-filled combination pH electrode, featuring a porous liquid junction. Model: RPY

NIST Certification: Certificates are available that confirm NIST traceability of an instrument (Order #MC) or Standard Solution/pH Buffer (Order #SC). Note: Both MC Certificates and/or SC Solution Certificates must be specified when placing instrument/solution orders.



Model EP-11/pH
Our most popular pDS model features four conductivity ranges and a 2-12 pH range

Model 532T1
Our most popular model for many years, this instrument offers three very useful ppm ranges.

Model EP-10
With its four micromho ranges, this instrument is ideal for most water treatment applications.

Model EP
The most versatile of all DS Meters, this instrument is capable of testing both ultra pure and ocean waters...and everything in between!

Downloadable Files